data center ups
"
Visench Industriepräzisions-Klimaanlage Kühlwasserkonfiguration für Rechenzentrum
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW)40.450.660.4Sensible cooling capacity (kW)3746.355.1sensible heat
Datenzentrum Klimaanlage mit Oberluftversorgungsraum Industrieklimaanlage
Product Description Specification Room-level precision air conditioning technical parameters and configuration table (single system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA1025UCMA1030UCMA1035UCMA1040UOutdoor unit modelCMT025SPCMT040SPCMT045SPCMT050SPEnergy efficiency ratio3.013.093.053.01Power Specifications380VAC/50HZMaximum current26A35A39A42ARecommended input space40A/4P50A/4P63A/4P63A/4PCooling capacity (kW)20.230.535.440.2Sensible
Industrie-Klimaanlage für Rechenzentren mit einer Kühlleistung von 30 kW und einer Raumstärke von 3 KVA
Product Description Specification Room-level precision air conditioning technical parameters and configuration table (single system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA1025UCMA1030UCMA1035UCMA1040UOutdoor unit modelCMT025SPCMT040SPCMT045SPCMT050SPEnergy efficiency ratio3.013.093.053.01Power Specifications380VAC/50HZMaximum current26A35A39A42ARecommended input space40A/4P50A/4P63A/4P63A/4PCooling capacity (kW)20.230.535.440.2Sensible
20KW 380vac 20000W Kleines Rechnerzimmer Präzision Industriefußboden stehende Klimaanlage für Rechenzentrum
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCNA1008F3Z3ACNA1013F3Z3ACNA1008F1Z3ACNA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration
R410 Kältemittel 5000 m3/h Luftstrom Raum-Präzisions-Klimaanlage für Rechenzentrum
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible
380VAC/50HZ-Klimageräte der Visench CRA-Serie für Rechenzentren
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible
Modell 2*CMT025SP Industriepräzisions-Klimaanlage für Rechenzentrum von Visench
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW)40.450.660.4Sensible cooling capacity (kW)3746.355.1sensible heat
EC-Ventilator Visench CRA-Serie 12.5KW Raum-Präzisions-Klimaanlage für Rechenzentrum
CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible
130 kg CSA1008F1Z3A 8KW 13KW 17KW 20KW Raum-basierte Luftgekühlte Industrie-Präzisions-Klimaanlage für Rechenzentrum
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCSA1008F3Z3ACSA1013F3Z3ACSA1008F1Z3ACSA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration