data center ups
"
1280*995*1950 Industrielle Präzisions-Klimaanlage R410 EC Lüfter für die Kühlung von Rechenzentren
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW)40.450.660.4Sensible cooling capacity (kW)3746.355.1sensible heat
Datencenter Präzisions-Klimaanlage R410 EC Lüfter mit 11500m3/h Luftstrom und 450kg Gewicht
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW)40.450.660.4Sensible cooling capacity (kW)3746.355.1sensible heat
Visench 80KVA 90KVA 100KVA Doppelsystem-Luftkühlung Industriepräzisions-Klimaanlage R410 EC Ventilator für Rechenzentrum
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW)40.450.660.4Sensible cooling capacity (kW)3746.355.1sensible heat
Hohe Sicherheitsstufe Visench 40KVA 50KVA 60KVA 70KVA Dual System Luftkühlung Industrielle Präzisions-Klimaanlage R410 EC Ventilator für Rechenzentrum
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW)40.450.660.4Sensible cooling capacity (kW)3746.355.1sensible heat
40KW 40KVA Dual-System-Luftkühlung Industrielle Präzisions-Klimaanlage für Rechenzentrum
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW)40.450.660.4Sensible cooling capacity (kW)3746.355.1sensible heat
Visench Industriepräzisions-Klimaanlage Kühlwasserkonfiguration für Rechenzentrum
Product Description Room-level precision air conditioning technical parameters and configuration table (dual system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA2040CMA2050CMA2060Outdoor unit model2*CMT025SP2*CMT033SP2*CMT040SPEnergy efficiency ratio3.053.033.04Power Specifications380VAC/50HZMaximum current44A52A57ARecommended input space63A/4P63A/4P80A/4PCooling capacity (kW)40.450.660.4Sensible cooling capacity (kW)3746.355.1sensible heat
Datenzentrum Klimaanlage mit Oberluftversorgungsraum Industrieklimaanlage
Product Description Specification Room-level precision air conditioning technical parameters and configuration table (single system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA1025UCMA1030UCMA1035UCMA1040UOutdoor unit modelCMT025SPCMT040SPCMT045SPCMT050SPEnergy efficiency ratio3.013.093.053.01Power Specifications380VAC/50HZMaximum current26A35A39A42ARecommended input space40A/4P50A/4P63A/4P63A/4PCooling capacity (kW)20.230.535.440.2Sensible
Industrie-Klimaanlage für Rechenzentren mit einer Kühlleistung von 30 kW und einer Raumstärke von 3 KVA
Product Description Specification Room-level precision air conditioning technical parameters and configuration table (single system)Air conditioner typeConstant temperature and humidity typeIndoor unit modelCMA1025UCMA1030UCMA1035UCMA1040UOutdoor unit modelCMT025SPCMT040SPCMT045SPCMT050SPEnergy efficiency ratio3.013.093.053.01Power Specifications380VAC/50HZMaximum current26A35A39A42ARecommended input space40A/4P50A/4P63A/4P63A/4PCooling capacity (kW)20.230.535.440.2Sensible
20KW 380vac 20000W Kleines Rechnerzimmer Präzision Industriefußboden stehende Klimaanlage für Rechenzentrum
Product Description Specification Technical parameters and configuration table of precision air conditioners for small computer roomscategoryConstant temperature and humidity typeCooling onlyIndoor unit modelCNA1008F3Z3ACNA1013F3Z3ACNA1008F1Z3ACNA1013F1Z3AOutdoor unit modelCST008SP1ACST013SP1ACST008SP1ACST013SP1AEnergy efficiency ratio3.03.03.03.0Power Specifications380VAC/50HZIndoor unit maximum current11.5A15.5A7A12AOutdoor unit maximum current1.1A2.2A1.1A2.2ARefrigeration